Still Thoughts Hall, Zhuchi Foundation, Wen Shin Road, Taichung
Location: Taichung City
Architect: Dai Yu Ze Architects and Associates
Stories: B2F+8F
Structure: SRC
System: Dual System(SMRF+Buckling Inhibited Brace)
Area: 41500 m2
Design: 2007

Earthquake Resisting Device: BRB 30m Roof Span
  • Earthquake Resisting Device (BRB): The BRB devices, patented by National Science Council, were installed on 1F-7F.

  • The building is designed to be a meeting hall, which. requires a roof span of 30m. Therefore, the long beam must bear a live load of 500kgf/m2. A steel beam with a length of 15m was made to match up with the camber.

     

 

 
 